(3) Wipe the surface of the photosensitive drum with a cotton swab until the dust
or paper powder on the surface comes off.
Toner cartridge
Caution:
Do not wipe the surface of the photosensitive drum with something sharp. (ball-point
pen etc.)
Use cleaning liquid which is a 50-50 mixture of ethyl alcohol and pure water.
I-16
Black band
<Printing>
Possible cause
Step
Drum unit
Ditto
Paper path
Separator
Photosensitive drum
Check
1
Is the wire cleaner positioned
at its home position?
2
Is the corona wire dirty?
Fig. 4-4
Result
No
Yes
IV-18
Cleaning roller
Remedy
Return the wire cleaner to its
home position.
Clean the corona wire.
If the problem still appears
after cleaning, replace the
drum unit.