14.38 Turning On Time Request; System Control Command Type 1 - Canon VC-C50i/VC-C50iR Programmer's Manual

Communication camera
Table of Contents

Advertisement

14.38 Turning ON Time Request

Function
To request total accumulated turn ON time.
Command
0092h
Parameter
Length
Value
Status
Length
Range
Reference
•Camera accumulated turn ON time calculates total camera turn ON time in
one hour as one unit.
•Pedestal accumulated turn ON time calculates total power on time in one
hour as one unit.
Format of Control Code
d0
d1
Header
Device Num
FFh
30h
Request of total turn on time (0:camera section/1:pedestal section) indicates in
ASCII code 1 byte.
Example: to request total accumulated time of pedestal section
Answer Format
In case of No Error
d0
d1
Header
Device Num
FEh
30h
Total accumulated turn on time indicates in hexadecimal 4 figures and
status value is its ASCII code.
Example:
573 hours
In case of Error
d0
d1
Header
Device Num
FEh
30h
Error Flag indicates in 2 figures hexadecimal and returns ASCII code value.
Example:
In case of Parameter Error :
In case of Mode Error :
Condition of Error flag to be set
Parameter Error •In case of assigned parameter illegal.
Mode Error
1 byte
0h: accumulated turn ON time of camera section
1h: accumulated turn ON time of pedestal section
4 byte
0000h~FFFFh
d2
d3
Command
3Xh
00h
p0
01h
31h
d2
d3
d4
Error Code
3Xh
30h
30h
023Dh ⇒
d2
d3
Error Code
3Xh
e0
01010000B ⇒ 50h ⇒ 35h 30h
10010000B ⇒ 90h ⇒ 39h 30h
•Not in status of Camera ON.
•Not in status of Host Control Mode.

System Control Command Type 1

d4
d5
Parameter
92h
p0
d5
d6
Status
s0
s1
s0
s1
30h
32h
d4
d5
End mark
e1
EFh
175
d6
End mark
EFh
d7
d8
End mark
s2
s3
s2
s3
33h
44h
e0 e1
d9
EFh

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vc-c50i

Table of Contents