Setdrgroupdestinationaccess; Setdrgroupfailsafe - HP 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure Command Reference Manual

Job command reference
Hide thumbs Also See for 418800-B21 - StorageWorks Modular Smart Array 70 Storage Enclosure:
Table of Contents

Advertisement

Comments. Enter your comment text.
Examples
SetDrGroupComments ( "\\ArrayA2\DrGroupPets","Replicates between SiteA and SiteB" )
Comments
Associated validation commands. None
Agent and license prerequisites. Requires remote replication licenses on the source and
destination storage systems.
Command result value. None. For a complete list, see
OS specifics. None
See
resource names and UNC

SetDrGroupDestinationAccess

Specifies the destination host access mode of a DR group pair.
Syntax and arguments
When initially inserted into a job, the command syntax and default arguments are:
SetDrGroupDestinationAccess ( %drgroup_unc_name%, NONE )
UNC DR Group Name (%drgroup_unc_name%). Select or enter the UNC name of the destination DR
group in the DR group pair.
Destination Access. Select or enter the destination access type. Choices are none, read_only, and
no_read.
Examples
SetDrGroupDestinationAccess ( "\\ArrayA2\DrGrpPets", READ_ONLY )
Comments
Associated validation commands. None
Agent and license prerequisites. Remote replication licenses are required on the source and
destination storage systems.
Command result value. None. For a complete list, see
OS specifics. None
See
resource names and UNC

SetDrGroupFailsafe

Specifies the failsafe mode (failsafe on unavailable member) of a DR group pair.
Syntax and arguments
When initially inserted into a job, the command syntax and default arguments are:
SetDrGroupFailsafe ( %drgroup_unc_name%, DISABLED )
UNC DR Group Name (%drgroup_unc_name%). Select or enter the UNC name of the DR group to
be changed.
command result
formats.
command result
formats.
HP StorageWorks Replication Solutions Manager 4.0.1
values.
values.
143