CDA RV 1200 Series Installation Instructions Manual page 61

Table of Contents

Advertisement

Electrical feeder cable
connection
To connect the feeder cable to the cooker
it is necessary to:
– Remove the 6 screws that hold shield A
behind the cooker.
– Open completely the cable clamp D.
– Position the U bolts onto terminal block
B (fig. 63) according to the diagram in
fig. 64 and fig. 65.
– Insert the feeder cable into the cable
save P. The supply cable must be of a
suitable size for the current requirements
of the appliance; see the section
"Feeder cable section".
– Connect the phase and earth cables to
terminal B according to figures 64 and
65.
– Pull the feeder cable and block it with
the cable clamp D.
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
B
D
P
Feeder cable section
type H05RRF
230 V
Connection with wall box connection.
(**) –
– Diversity factor applied
– A diversity factor may be applied to
the total loading of the cooker only by
a suitable qualified person.
A
Fig. 63
3 x 4 mm
230 V
1 2 3 4 5
L
N (L
1
PE
Earth
N
Neutral
L
Live
Red
or
Brown
L1
(Live)
Black
or
N
Blue
(L
)
2
(Neutral)
PE
Green
and
Yellow
(Earth)
2
(**)
Fig. 64
)
PE
2
Fig. 65
230 V ~
61

Advertisement

Table of Contents
loading

Table of Contents