8-4 Compaq ProLiant 8500 Servers Setup and Installation Guide
1
3
5
7
9
11
13
15
17
Figure 8-1. Accessing System Interconnect Status Indicator LEDs
System Interconnect Status Indicators
Indicator
Component
1
Emergency Shutdown
2
Processor 8
3
Processor 7
4
Processor 6
5
Processor 5
6
Processor 4
7
Processor 3
8
Processor 2
9
Processor 1
Note 1: AC power to the system has been cut to avert imminent component damage and
data loss. Reasons for this could include: the failure of the terminator PPM, the fan
controller has stopped responding, or the system has recorded a temperature violation.
Note 2: A power supply has stopped providing adequate power as per system
specifications, the system has experienced a short, a PPM has failed, or a reboot has been
initiated via Automatic Server Recovery (ASR-2).
2
4
6
8
10
12
14
16
Table 8-1
Indicator
1
-
q
w
e
r
t
y
u
Component
Termination PPM
Memory
Processor/Memory Module
I/O Module
Media Module
SCSI backplane 1
SCSI backplane 2
2
System Reset

Advertisement

Table of Contents