Compaq ProLiant 8500 Setup And Installation Manual page 71

Compaq proliant 8500 setup and installation guide
Hide thumbs Also See for ProLiant 8500:
Table of Contents

Advertisement

3. Rotate the power supply handle down 2 and slide the supply out of the
chassis 3 as shown in the following figure.
NOTE: When you remove the power supply, a spring-loaded trap door will close to block
the opening. This door preserves the air path required to cool the internal components of
the server.
2
Figure 4-2. Removing a power supply
4. Remove the protective covers from the connector on the new power
supply. See the installation documentation that came with the power
supply for more information. Keep the protective covers for future
handling.
5. Lower the handle on the new hot-plug power supply.
6. Slide the hot-plug power supply into the power supply cage, pushing the
spring-loaded trap door open, until the supply is seated securely .
7. Raise the handle to lock the power supply into place . The power
supply fan will start immediately if the system is running.
3
Installing Hardware Options 4-3