Input 1 Connected To The Removable Media Bay - Compaq ProLiant 5500 Setup And Installation Manual

Pentium ii xeon processor-based servers
Hide thumbs Also See for ProLiant 5500:
Table of Contents

Advertisement

7-24
Cabling
Example 1:
Using Integrated SCSI Port 1 and Port 2 for
Hard Drives with SCSI Input 1 Connected to
the Removable Media Bay
1.
Install the Duplex Enabler Board on the back of the Drive Cage, if not
already installed.
2.
Connect 19-inch point-to-point non-terminated SCSI cable (199606-
007), from the SCSI Port 1 to SCSI Input 0 of the duplex board. Connect
another 19-inch point-to-point non-terminated SCSI cable (199606-007)
from SCSI Port 2 to SCSI Input 1 of the duplex board. These
connections are shown in Figures 7-13 and 7-14.
3.
Use 22-inch 3-device non-terminated SCSI cable (199616-010),
supplied with server, to connect from the duplex enabler board to the
removable media bay.
5
Figure 7-13.
3
2
1
3 3
3 3
2 2
2 2
6
1 1
1 1
0 0
0 0
7
Example 1: Configuration diagram
For use with Intel Pentium II Xeon processor-based servers only
4
8
9
10

Advertisement

Table of Contents
loading