Rack-Mount Server Installation
1.
Attach a mounting bracket assembly to the front of the rack first, using
one M6 x 1.0-12L Phillips screw in the bottom hole of the bracket. Do
not use the washers supplied with the Compaq rack.
Figure 3-10.
2. Carefully align the mounting bracket assembly with the rear rack frame.
3. Secure the back end of the mounting bracket assembly to the back corner
brace of the rack with one M6 x 1.0-12L Phillips screw through the
bottom hole of the bracket and the cage nut, as shown in the following
figure.
IMPORTANT: Use only the bottom hole of the bracket as shown in
Figure 3-10.
Attaching mounting bracket assembly to the front of the rack
For use with Intel Pentium II Xeon processor-based servers only