3.3.14 Floating VRM and EBL

Use the floating EBL function to move a VRM or an EBL.
Only #1EBL and #1VRM may be moved.

Setting the #1EBL and #1VRM to enable moving

Setting the #1EBL and #1VRM to enable moving
Setting the #1EBL and #1VRM to enable moving
Setting the #1EBL and #1VRM to enable moving
(a) Select "FLOAT" in the line "EBL1/VRM1" - the menu "FUNCTION".
The point of reference of #1EBL and center of #1VRM is now movable.
However, the location of the point of reference of #1EBL and the center of #1VRM
is always at the same position.

Setting the point of reference and center position

Setting the point of reference and cent
Setting the point of reference and cent
Setting the point of reference and cent
(a) Push the
The cross key will become the floating EBL or floating VRM.
The position information on the mark displayed by the marker is displayed at the
lower right of the screen.
The marker information is displayed only until the point of reference and center
positions are determined.
(b) Use the cross key and push the
The set marker position will be determined as the point of reference of #1EBL and
center of #1VRM.

Operating the EBL and VRM

Operating the EBL and VRM
Operating the EBL and VRM
Operating the EBL and VRM
The method of operation is the same as for normal EBL and VRM.
• Only "setting the point of reference/ center position" is operable and if the EBL
key had been pushed, the operation is only with #1EBL while if the VRM key
had been pushed, the operation is only with #1VRM.
• The point of reference and center position may be moved only for #1VRM and
#1EBL. Prior to operation, be sure to select either #1EBL or #1VRM.
Please refer to "3.3.11 Measuring the range to the target" - "1. Using VRM",
"3.3.13 Measuring the bearing of a target" - "1. Using EBL"

Canceling the point of reference or center position

Canceling the point of reference or center position
Canceling the point of reference or center position
Canceling the point of reference or center position
(a) Select "FIX" in the line "EBL1/VRM1" - the menu "FUNCTION".
The floating EBL will be canceled and the point of reference and center position
will be fixed to the location of the ship.