Advertisement

4.10.1 GPRS Communication Test

The GPRS Communication diagnostic procedure tests
GSM/GPRS communication and reports the diagnostic
result.
In
case
of
information of the failure is reported.
The following GSM/ GPRS messages are reported:
Message
Description
Unit is OK
GSM / GPRS is functioning correctly.
GSM comm.
The GSM/GPRS module does not
loss
communicate with the Panel
Pin code fail
Missing or wrong PIN code.
(Only if SIM card PIN code is enabled.)
GSM net. fail
Unit failed with registration to local
GSM network.
SIM card fail
SIM not installed or SIM card failure.
GSM not
GSM auto enroll failed to detect
detected
GSM/GPRS module.
No GPRS
The SIM card does not have the GPRS
service
service enabled.
GPRS conn.
Local GPRS network is not available
fail
or, wrong setting to GPRS APN, user
and/or password.
Srvr
IPMP Receiver cannot be reached –
unavailable
Check the Server IP
IP not defined
Server IP #1 and #2 are not configured.
APN not
APN is not configured.
defined
SIM card
After entering a wrong PIN code 3
locked
consecutive times the SIM is locked.
To unlock it enter a PUK number. The
PUK number cannot be entered by the
PowerMaxExpress.
Denied by
The
server
request. Check that the Panel is
registered to the IPMP Receiver.

4.10.2 LAN Connection Test

The
LAN
Connection
Broadband Module communication to the IPMP and
reports the diagnostic result. In case of communication
failure, detailed information of the failure is reported.
If the Broadband Module is not registered to the
PowerMaxExpress, the menu "LAN CONNECT.TEST" will
not be displayed.
The following LAN messages are reported:
Message
Description
Unit is ok
Broadband
correctly.
Test aborted
The diagnostic test is aborted, as
follows:
• AC failure – Broadband Module is
set to OFF mode.
• Broadband
completed the power-up procedure.
In this case, the installer should wait
a maximum of 30 seconds before
re-testing.
26
communication
failure,
IPMP
denies
the
diagnostic
procedure
Module
is
functioning
Module
has
Comm. loss
detailed
Rcvr Ip
missing
Cable
unplugged
Check lan
config
Rcvr#1
UnReach.
Rcvr#2
UnReach.
Rcvr#1 UnReg.
Rcvr#2 UnReg.
Broadband
Module
timeout err.
Invalid result
connection
tests
not
The RS-232 serial interface between
the
Broadband
Module
PowerMaxExpress failed.
Receivers IP 1 and 2 settings are
missing in the PowerMaxExpress.
The Ethernet cable is not connected
to the Broadband Module.
This message appears in any of the
following cases:
• Incorrect Broadband Module IP has
been entered.
• Incorrect subnet mask has been
entered.
• Incorrect default gateway has been
entered.
• DHCP server failure.
Receiver 1 or 2 is inaccessible, as
follows:
• Wrong receiver IP has been entered.
• Receiver failure.
• WAN Network failure.
The PowerMaxExpress unit is not
registered to IP receiver 1 or 2.
Broadband Module does not respond
to test result within 70 sec.
Broadband Module responds with a
result code that is not recognized by the
PowerMaxExpress.
and
the
D-302989