Quick Arm; Bypass; Exit Mode; Piezo Beeps - Visonic POWERMAXEXPRESS - INSTALLATION 2 Installer's Manual

Fully supervised wireless alarm control system
Table of Contents

Advertisement

4.4.7 Quick Arm

(Fig. 4.4, location 07). Here you determine whether the
user will be allowed to perform quick arming or not. Once
quick arming is permitted, the control panel does not
request a user code before it arms the system.
The two options are: quick arm ON and quick arm OFF.

4.4.8 Bypass

(Fig. 4.4, location 08). Here you permit either manual
bypassing
of
individual
SETTINGS menu), or allow the system to "force arm"
(perform automatic bypassing) of open zones during the
exit delay. If desired, press the arming key again if you want
to eliminate the protest tone that sounds during forced
arming. If a zone is open and forced arming is not
permitted, "NOT READY" is displayed and the system does
not arm (the "Sad Melody" will sound). If "no bypass" is
selected, neither manual bypassing nor force arming is
allowed.
Options: manual bypass, force arm and no bypass.
Note: To comply with EN requirements, "manual bypass"
or "force arm" must be selected.

4.4.9 Exit Mode

(Fig. 4.4, location 09). Here you determine exit mode
options. Three types of exit modes are available:
Restart Exit - Exit delay restarts when the door is
reopened during exit delay. The restart occurs once only.
Restarting the exit delay is helpful if the user re-enters
immediately after going out to retrieve an item that he left
behind.
Off by door - When the door is closed, the exit delay is
automatically terminated (even if the defined exit delay
was not completed).
Normal - The exit delay is exactly as defined, regardless
of whether the door is open or closed.
Restart + Arm Home - Exit delay restarts when the door is
reopened during exit delay. In the case that no door was
opened during exit delay "AWAY", the control panel will be
armed "HOME".

4.4.10 Piezo Beeps

(Fig. 4.4, location 10). Here you determine whether
warning beeps will sound or muted during exit and entry
delays. An additional option is to mute the warning beeps
only when the system is armed "HOME".
Options: enable beeps, off when home and disable beeps.
Note: When exit beeps are disabled toward the end of a
delay, the happy (success) melody will sound.

4.4.11 Trouble Beeps

(Fig. 4.4, location 11). Under trouble conditions, the
sounder emits a series of 3 short beeps once per minute.
Here you determine whether this special beeping
sequence will be active, inactive, or just inactive at night
(the range of "night" hours is defined in the factory). The 3
options are: enable beeps, off at night (8 PM through 7
AM) and disable beeps.

4.4.12 Panic Alarm

(Fig. 4.4, location 12). Here you determine whether the
user will be allowed to initiate a panic alarm by
simultaneous pressing either the two panic buttons (on the
keypad / wireless commander) or away + home (on a
keyfob transmitter). Audible panic activates the siren and
simultaneously transmits a message via telephone. Silent
panic only transmits a message via telephone. The options
are: silent panic, audible panic and disable panic.
14
zones (through the USER

4.4.13 Swinger Stop

(Fig. 4.4, location 13). Here you determine the number of
times each zone is allowed to initiate an alarm within a
single arming/disarming period (including tamper & power
failure events of detectors, PowerMaxExpress, wireless
siren, etc.). If the alarms number from a specific zone
exceeds the programmed number, the control panel
automatically bypasses the zone to prevent recurrent siren
noise and nuisance reporting to the central station. The
zone will be reactivated upon disarming, or 48 hours after
having been bypassed (if the system remains armed).
Available options are: shut after 1, shut after 2, shut
after 3 and no shutdown.

4.4.14 Cross Zoning

(Fig. 4.4, location 14). Here you determine whether cross
zoning will be active or inactive. Cross zoning is a method
used to counteract false alarms - an alarm will not be
initiated unless two adjacent zones are violated within a
30-second time limit.
This feature is active only when arming AWAY and only
with zone couples from zone No. 18 to 27 (18 and 19, 20
and 21, etc.). You may use any one of these zone couples
to create a "cross-zoned" area.
Note: If one of two crossed zones is bypassed (see Para.
4.4.8), the remaining zone will function independently.
Note: Every 2 crossed zones must be of the allowed zone
type (Interior, Perimeter, Perimeter follower).
The options are: cross zone ON and cross zone OFF.
Note: A common zone should not be defined as a cross
zone.
Cross zoning is not applicable in Entry/ Exit zones and
24h zones (Fire, Emergency, 24h audible, 24h silent).

4.4.15 Supervision

(Fig. 4.4, location 15). Here you determine the time limit for
reception of supervision reports from various supervised
wireless devices. If any device does not report at least
once within the selected time limit, an "INACTIVITY" alert
is initiated.
The options are: 1, 2, 4, 8, 12 hours and disable.
Note: To comply with EN requirements, 1 or 2 hours must
be selected.

4.4.16 NOT READY

(Fig. 4.4, location 16). Here you determine if the system
will be in NOT READY status when there is a supervision
failure. In the "in supervision" mode, the system will be in
NOT READY status if during the last 20 minutes a
supervision message was not received. Options: normal
and in supervision.
Note: To comply with EN requirements, "in supervision"
must be selected.

4.4.17 AUX Button A

(Fig. 4.4, location 17). Here you select the function of the
AUX button/ button A on keyfob transmitters MCT-234,
MCT-237 and wireless commanders MCM-140+. Two
options are offered for each AUX button:
Instant: Pressing the AUX button while the exit delay is in
progress will cause the system to arm "instant" (the entry
delay is canceled).
Skip exit delay: Pressing the AUX button will immediately
cause the system to arm immediately.

4.4.18 AUX Button B 2-W-KF

(Fig. 4.4, loc. 18). Applicable only for 2-way keyfob
MCT-237. Same as 4.4.17 but for AUX button B.
D-302989

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaxexpress

Table of Contents