ENROLLING TYPE
normal enroll
by tamper
(First display)
READY 00:00
WALK TEST
USER SETTING
INSTALLER MODE
ENTER CODE
[installer code]
1. NEW INSTL CODE
2. ENROLLING
3. DEFINE ZONES
<OK> TO EXIT
Figure 4.2 - Enrolling / Deleting Wireless Devices / Keyfobs / Wireless Commanders / Wireless Sirens
*
Keyfob enrolling can be performed by the installer or by
the user (via USER SETTINGS menu).
** A black box in the display means that a device is
enrolled (the system has learned its ID). No black box
indicates that the device is not enrolled.
D-302989
ENROLL SENSORS
higher sensitivity
lower sensitivity
[wired Zone No.
29/30] (e.g. 29)
ZONE No: 29
ZONE No: 05
<OK> TO ENROLL
TRANSMIT NOW
[Initiate transmission)
ZONE No: 29
ZONE No: 05
for next
enrolling action
enrolling action
Enrolling wired sensor
Enrolling a WL Sensor
ENROL WL 1WAY KP
1way kp No :
[WL 1-way keypad
No. 1 to 8] (e.g. 5)
1way kp No : 5
TRANSMIT NOW
press
*
key until
red LED
lights
1way kp No: 5
for next
enrolling action
Enrolling a wireless
Commander MCM-140+
ENROL WL SIREN
SIREN No :
[WL siren No.
1 or 2] (e.g. 2)
siren No : 2
TRANSMIT NOW
Momentarily press the
wireless siren self-test
button until a squawk is
heard (1 sec. approx.)
siren No: 2
for next
enrolling action
Enrolling a
wireless siren
SET SENSITIV.
(****)
Select by
or
ZONE No: - -
[WL Zone No.
[wired/WL Zone No.
01-28] (e.g. 05)
01-30] (e.g. 05)
ZONE No: 05
<OFF> TO DELETE
(**)
(***)
ZONE No: 05
for next
Deleting wired/
WL sensor
(**)
1way kp No : 5
<OFF> TO DELETE
1way kp No: 5
Deleting a wireless
Commander MCM-140+
(**)
siren No : 2
Open WL
siren cover
and remove
its battery
<OFF> TO DELETE
siren No: 2
Deleting a
wireless siren
***
Initiate either normal transmission or the device
tamper function (see ENROLLING TYPE, Par. 4.2.2).
**** Select "higher" sensitivity for far wireless device,
"lower" for near devices.
(*)
ENROLL KEYFOB
Keyfob No: -
[Keyfob No.]
Keyfob No: 5
TRANSMIT NOW
(press
any
key)
(**)
KEYFOB No: 05
(**)
for next
enrolling action
Enrolling a Keyfob
ENROL WL 2WAY KP
2way kp No:
[MKP-150/151
No. 1 or 2] (e.g. 2)
2way kp No : 2
TRANSMIT NOW
Press MKP-
150/151
back tamper
switch once
(see MKP-
150/151
AWAY
inst. instructions)
2way kp No: 2
for next
enrolling action
Enrolling a wireless
keypad MKP-150/151
(**)
(e.g. 5)
Keyfob No: 5
<OFF> TO DELETE
KEYFOB No: 05
Deleting a Keyfob
(**)
2way kp No : 2
<OFF> TO DELETE
2way kp No: 2
Deleting a wireless
keypad MKP-150/151
11