A3. Emergency Transmitter List; A4. Non-Alarm Transmitter List; Appendix B. Event Codes; Contact Id Event Codes - Visonic POWERMAXEXPRESS - INSTALLATION 2 Installer's Manual

Fully supervised wireless alarm control system
Table of Contents

Advertisement

A3. Emergency Transmitter List

Tx #
Transmitter Type
1
2
3
4
5
6
7
8
9
10

A4. Non-Alarm Transmitter List

Tx #
Transmitter Type
1
2
3
4
5
6
7
8
9
10

APPENDIX B. Event Codes

Contact ID Event Codes

Code
Definition
101
Emergency
110
Fire
120
Panic
121
Duress
122
Silent
123
Audible
131
Perimeter
132
Interior
134
Entry/Exit
137
Tamper/CP
139
Burglary verified
151
Gas alarm
154
Flood alarm
180
Gas trouble
301
AC loss
302
Low system battery
311
Battery disconnect
313
Engineer reset
321
Bell
344
RF receiver jam detect
350
Communication trouble

4/2 Event Codes

Note: The report to central station is on the following zones: First wireless siren - zone 31, second wireless siren - zone 32,
GSM - zone 33, first 2-way keypad (MKP-150/MKP-151) - zone 35, second 2-way keypad (MKP-150/MKP-151) - zone 36.
D-302989
Enrolled to Zone
Enrolled to Zone
Code
Definition
351
Telco fault
373
Fire detector trouble
381
Loss of supervision
RF
383
Sensor tamper
384
RF low battery
393
Fire detector clean me
401
O/C by user
403
Auto arm
406
Cancel
408
Quick arm
426
Door open event
441
Armed home
454
Fail to close
455
Fail to arm
456
Partial arm
459
Recent close event
570
Bypass
602
Periodic test report
607
Walk test mode
641
Senior watch trouble
Name of holder
Name of holder

SIA Event Codes

Code
Definition
AR
AC Restore
AT
AC Trouble
BA
Burglary Alarm
BB
Burglary Bypass
BC
Burglary Cancel
BR
Burglary Restore
BT
Burglary Trouble /
Jamming
BV
Burglary Verified
BZ
Missing Supervision
CF
Forced Closing
CI
Fail to Close
CL
Closing Report
CP
Auto Arm
CR
Recent Close
EA
Door Open
FA
Fire Alarm
FT
Fire Detector Clean
FJ
Fire detector trouble
FR
Fire Restore
GA
Gas alarm
GR
Gas alarm restore
GT
Gas trouble
Assignment
Code
Definition
GJ
Gas trouble restore
HA
Holdup Alarm (duress)
LR
Phone Line Restore
LT
Phone Line Trouble
OP
Opening Report
OT
Fail to Arm
PA
Panic Alarm
QA
Emergency Alarm
RN
Engineer Reset
RP
Automatic Test
RX
Manual Test
RY
Exit from Manual Test
TA
Tamper Alarm
TR
Tamper Restore
WA
Flood alarm
WR
Flood alarm restore
XR
Sensor Battery Restore
XT
Sensor Battery Trouble
YR
System Battery Restore
YT
System Battery Trouble /
Disconnection
YX
Service Required
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaxexpress

Table of Contents