2 ] Interface Cable Connection - Denso BHT-6000 User Manual

Denso bar code handy terminal user's manual bht-6000
Table of Contents

Advertisement

[ 2 ] Interface Cable Connection

As illustrated below, connect the CU-6000 (which is joined with the BHT-6000) to a host
computer with a cross-mode cable. To connect it to a modem, use a straight-mode
cable.
CU-6000
(DTE)
Cable Connection between CU-6000 and Host Computer
CU-6000
(DTE)
DTE and DCE
In the RS-232C interface specifications, the DTEs (Data Terminal Equipment) shall be
generally connected with each other by a cross-mode cable; the DTE and DCE (Data
Circuit-terminating Equipment) shall be connected with each other by a straight-mode
cable.
The DTE is one piece of equipment connected at both ends of a communications line
as a sender or receiver of data (such as CU-6000 joined with the BHT-6000 and a host
computer).
The DCE is one piece of equipment connected to the intermediate point between the
DTE and the communications line. It terminates communications lines and exchanges
information between those lines without any change in contents (such as modem).
1
2
3
4
5
6
7
8
20
1
2
3
4
5
6
7
8
20
Cable Connection between CU-6000 and Modem
145
Chapter 5. Handling the CU-6000 (Option)
Host Computer
(DTE)
FG
SD
RD
RS
CS
DR
SG
CD
ER
Modem
(DCE)
FG
SD
RD
RS
CS
DR
SG
CD
ER