Lexicon
7.3.8 Host Sleep
By transmitting the Sleep command, the Host indicates it has just "powered down" and will no
longer respond to RV-8 Notifications. No Acknowledgment is expected. The Host is assumed to
be asleep upon power up of the RV-8. Host status is maintained during standby.
7.3.8.1 Packet Description
7.3.8.2 Data Description
7.3.9 Get Communication Configuration
This command is a request to the RV-8 for the current communications configuration for the
serial port and protocol. The RV-8 responds to this command with a Communication
Configuration Packet.
7.3.9.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
7.3.9.2 Communication Configuration Response Packet
Application Header:
Command
Data Count
Application Data:
Data[0]
7.3.9.3 Data Description
Data Word
Bit
0
0
0
1
Acknowledge Enable:
TRUE Indicates the RV-8 will transmit Acknowledge Notification's to the Host.
FALSE Indicates the RV-8 will not transmit any positive Acknowledge
Parameter Change Enable:
TRUE Indicates the RV-8 will transmit any parameter change Notification as
FALSE Indicates the RV-8 will not transmit parameter change Notifications.
Application Header:
Command
HOST_SLEEP
Data Count
0
Application Data:
N/A
N/A
DC_CMD_GET_COM_CONFIG
0
N/A
DC_RESP_COM_CONFIG
1
Configuration Register 0
Definition
Acknowledge Enable
Parameter Change Enable
Notification messages. The RV-8 will always transmit NAK error
notification messages.
specified in the Parameter Change Notification Message.
RV-8 Serial Communications Protocol
0x12
0x00
0x2F
0x00
0x8C
0x01
nn
19