Rv8 Parameter Notification By Id - Lexicon RV-8 V2.0 - SERIAL PROTOCOL DEFINITIONS REV 1-8 Manual

Serial protocol definition
Table of Contents

Advertisement

Lexicon
7.1.4.4 Supported System Parameters
The following parameters will be supported by this Parameter Change Notification:
Parameter
1
Current Effect
Mute
System Volume
Balance
Input Selection
3
Zone 2 Mute
Bass
Treble
Loudness
Tilt
Menu Background On/Off
Notes:
(1) Returns legacy values which do not correspond to values in current software release.
(2) VOLUME = value -80.
(3) Zone 2 Mute notification does not respond to user muting, only when system responds to
other events, such as a Listening Mode change.

7.1.5 RV8 Parameter Notification by Id

RV-8 will transmit parameter change notifications if they are enabled using the command
described in 7.3.19 (MC12_Set_Parameter_Notification_By_Id). If a parameter value is changed
due to any user action or system action the RV8 will transmit the current value of the parameter
that is changing.
7.1.5.1 Command Packet Description
Application Header:
Command
Data Count
Application Data:
Data[0]
Data[1]
Data[2]
Data[3-23]
7.1.5.2 Data Description
Same as Paragraph 7.3.37.2
7.1.5.3 HOST Response
The RV-8 does not expect any response from the HOST.
DC Parameter Name
PROGRAM
MUTE
2
VOLUME
LR_BALANCE
1
INPUT
Z2_MUTE
BASS
TREBLE
LOUDNESS
TILT
MENU_BKGND
MC_PARAM_NOTIFICATION_BY_ID
24
ParamId(LSB)
ParamId(MSB)
ParamType
Value[0 -20]
RV-8 Serial Communications Protocol
DC Param Hex
Code
0x01
0x 03
0x 05
0x 06
0x 07
0x9D
0x A7
0x A8
0x A9
0x AE
0x BE
0x05
0x18
nn
nn
nn
nn nn
nn...
11