Get Input Name By Id - Lexicon RV-8 V2.0 - SERIAL PROTOCOL DEFINITIONS REV 1-8 Manual

Serial protocol definition
Table of Contents

Advertisement

Lexicon
7.3.29.2 Data Description
Value:
Data Type:
Max:
Min:
7.3.29.3 RV-8 Response
The RV-8 will assign the value from the packet to the Zone 2 balance.
7.3.29.4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the RV-8 will ignore the
command and transmit a NAK command with an error code DC_INVALID_DATA.

7.3.30 Get Input Name by Id

This command is a request to R-8 for the custom input name. RV-8 will respond with "Input Name
Packet".
7.3.30.1 Command Packet Description
Application Header:
Command MC_CMD_GET_INPUT_NAME
Data Count 1
Application Data:
Data[0]
7.3.30.2 Data Description
InputId:
Data Type:
Definition/Conversion: Appendix F RV-8 Input Ids
7.3.30.3 Data Validation
The InputId must be a valid Input number. If it is not the RV-8 will respond with a NAK packet
and error code DC_INVALID_INPUT.
7.3.30.4 Input Name Response Packet
Application Header:
Command
Data Count
Application Data:
Data[0]
Data[1]- Data[DataCount-1] InputName
7.3.30.5 Data Description
InputId:
Data Type:
Definition/Conversion: Appendix F RV-8 Input Ids
Signed 8-bit integer (2's compliment)
+16 (0x10) (Full Right)
-16 (0xF0) (Full Left)
InputId
Unsigned 8-bit Integer
MC_RESP_INPUT_NAME
Number of Characters in
InputName + 2
InputId
Unsigned 8-bit Integer
RV-8 Serial Communications Protocol
0x47
0x01
nn
0x96
nn
nn
ch ch ch ... 0x00
38

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rv-8

Table of Contents