Rv-8 Parameter Change - Lexicon RV-8 V2.0 - SERIAL PROTOCOL DEFINITIONS REV 1-8 Manual

Serial protocol definition
Table of Contents

Advertisement

Lexicon

7.1.4 RV-8 Parameter Change

RV8 will transmit predetermined parameter change notifications. If a parameter value is changed
due to any user action or system action the RV8 will transmit the current value of the parameter
that is changing.
The Supported System Parameters table listed below indicates which Parameters will
automatically transmit change notifications.
Note: These notifications will be transmitted even after the command 7.3.21 Clear All Parameter
Notifications has been sent.
7.1.4.1 Notification Packet Description
Application Header:
Command
Data Count
Application Data:
Data[0]
Data[1]
7.1.4.2 Data Description
ParamId:
Data Type:
Max:
Value:
The Current Value for this system parameter.
Data Type:
Max:
7.1.4.3 HOST Response
The RV-8 does not expect any response from the HOST.
DC_PARAM_CHG_MSG
2
ParamId
Value
Unsigned 8 bit integer
255.
Unsigned 8 bit integer
Set by the Max Value per the Parameter Definition response
Packet for the Parameter Id of this packet.
RV-8 Serial Communications Protocol
0x04
0x02
nn
nn
10