Set System Volume; Set Main Balance - Lexicon RV-8 V2.0 - SERIAL PROTOCOL DEFINITIONS REV 1-8 Manual

Serial protocol definition
Table of Contents

Advertisement

Lexicon
Zone 3 Balance:
Data Type:
Max:
Min:

7.3.24 Set System Volume

This command is a request to the RV-8 to set the system volume with the value in this packet.
7.3.24.1 Command Packet Description
Application Header:
Command MC_CMD_SET_SYS_VOLUME
Data Count 1
Application Data:
Data[0]
7.3.24.2 Data Description
Value:
Data Type:
Max:
Min:
7.3.24.3 RV-8 Response
The RV-8 will assign the value from the packet to the system volume.
7.3.24.4 Data Validation
If a value is passed that exceeds the maximum value of that parameter the RV-8 will ignore the
command and transmit a DC_NAK command with an error code DC_INVALID_DATA.

7.3.25 Set Main Balance

Commands RV-8 to set the system balance to the value in this packet.
7.3.25.1 Command Packet Description
Application Header:
Command
Data Count 1
Application Data:
Data[0]
7.3.25.2 Data Description
Value:
Data Type:
Max:
Min:
7.3.25.3 RV-8 Response
Signed 8-bit integer (2's compliment)
16 (0x10) (Full Right)
-16 (0xF0) (Full Left)
Value
Signed 8-bit integer (2's compliment)
+12 (0x0C) (12 dB)
-80 (0xB0) (-80 dB)
DC_CMD_SET_SYS_BALANCE
Value
Signed 8-bit integer (2's compliment)
+16 (0x10) (Full Right)
-16 (0xF0) (Full Left)
RV-8 Serial Communications Protocol
0x40
0x01
nn
0x41
0x01
nn