Max Value:
This is a 16 bit value representing the maximum value for a parameter.
Parameter values exceeding the maximum will be limited to the maximum. This
may be a signed or unsigned value depending on the Parameter Type.
Min Value:
This is a 16 bit value representing the minimum value for a parameter.
Parameter values exceeding the minimum will be limited to the minimum. . This
may be a signed or unsigned value depending on the Parameter Type.
Parameter Path:
This is a zero terminated ASCII character string describing the parameter's name
and path in the units parameter tree structure.
Read Only:
Data Type:
TRUE:
FALSE:
7.3.14 Set Parameter Value by Id
RV8 Set Parameter by Id command sets the parameter value equal to the value sent in the
command packet and then runs the appropriate functional changes associated with changing the
given parameter.
7.3.14.1 Command Packet Description
Application Header:
Command MC_CMD_SET_SYS_PARAM_VALUE_BY_ID 0x36
Data Count 24
Application Data:
Data[0]
Data[1]
Data[2]
Data[3-23] Value[0 -20]
7.3.14.2 Data Description
ParamId:
Data Type:
Max Value:
ParamType:
Param Type Name
PARAM_TYPE_UINT8
PARAM_TYPE_UINT16
PARAM_TYPE_CSTR8
Boolean
Parameter is read only
Parameter is writeable
ParamId(LSB)
ParamId(MSB)
ParamType
Unsigned 16-bit Integer
Max Parameter Count as reported by the RV-8 Unit Configuration
Response Packet in 7.3.16.2
Param
Type
ID
0
1
2
RV-8 Serial Communications Protocol
Type Description
Unsigned 8 bit integer(0 to
255)
Unsigned 16 bit integer(0 to
65535)
Zero terminated string of 8
ascii characters
0x18
nn
nn
nn
nn nn nn...
Data
Size
(Bytes)
1
2
9
24