12-16/60 Transducer - Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installation Manual

Echo sounder transducers
Table of Contents

Advertisement

Simrad Echo sounder transducers

12-16/60 transducer

Configuration NARROW
Transducer
cable
Brown
Blue
Yellow
Black
Screen
Configuration WIDE
Transducer
cable
Brown
Blue
Yellow
Black
Screen
W802-10
Rev.A
62
This is the termination of the transducer cable from the 12–16/60
single or dual beam transducer to the transducer socket on the
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently fixed to the transducer.
Note
Always check the transmit power if wide beam is selected in
order not to exceed the power capacity on the transducer.
Junction Box (1:1)
(Optional)
Junction Box (1:1)
(Optional)
12-16/60 Transducer cable termination
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
GPT Transducer
A
N
socket
B
M
C
L
D
K
E
J
F
H
Connect to plug housing
Connect to plug housing
C
D
C
D