Es38-10 Transducer - Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installation Manual

Echo sounder transducers
Table of Contents

Advertisement

ES38–10 transducer
2
1
Sections seen from top
of the transducer
ES38-10
transducer cable
White
1
Black
White
2
Black
White
3
Black
Screen
W802-8
Rev.A
851-160164/H
This is the termination of the transducer cable from the ES38–10
split-beam transducer to the transducer socket on the ES60 and
EK60 General Purpose Transceiver Unit (GPT). The other end of
the cable is permanently fixed to the transducer.
3
FWD
Junction Box (1:1)
(Optional)
ES38-10 Transducer cable termination
There are four pairs in the transducer cable, each with one black
and one white cable. Each pair is marked with a small label
identifying the transducer section. Pair number 4 is not used.
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
GPT transducer terminations
GPT Transducer
A
N
socket
B
M
C
L
D
K
E
J
F
H
Connect to plug housing
J
H
F
E
D
C
61