Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installation Manual page 31

Echo sounder transducers
Table of Contents

Advertisement

Ways of mounting the transducer
Example
The transducer shown in the figure below is mounted inside the
hull. The tank is filled with oil.
G
H
D
F
A
B
E
(CD017012C)
C
(A) = Steel tank
(B) = Oil
(C) = Hull plating
(D) = Cable service loop
(E) = Stuffing tube
(F) = Cable in steel conduit
(G) = Hole for oil filling
(H) = Air outlet
29
851-160164/H