Connecting Es38-18/200-18Cr Transducer To A 12-Pin Amphenol Socket - Simrad ES38-18/200-18CR Installation Manual

Table of Contents

Advertisement

Connecting ES38-18/200-18CR transducer
to a 12-pin Amphenol socket
The Simrad ES38-18/200-18CR transducer shall be connected to terminals
on a circular 12-pin Amphenol transducer socket. This socket is used on the General
Purpose Transceiver (GPT), and on some versions of the Wide Band Transceiver (WBT).
Sector
1
2
3
Single beam
Digital output
Digital ground
Cable screen
The cable screen must be connected to the housing on the transducer plug and to
terminal
.
N
Note
The black wires in the transducer cable are not for grounding. You must never connect
these together, and you must not connect any of them to vessel ground.
If you need to splice the transducer cable, we strongly recommend the use of a metal
junction box with proper cable glands. The cable screen must be connected to the cable
glands. The cable screen and the junction box chassis must not be connected to vessel
ground. Avoid ground loops. You must use the same type of cable as the original
transducer cable, contact Kongsberg Maritime for advice.
436200/A
Cable colours
Terminal on socket
White
Black
Green
Black
Yellow
Black
Blue
Black
Red
Black
Screen
Cable layout and interconnections
Transceiver channel
H
J
E
F
C
D
A
Single beam
B
L
M
N
through
A
N
1
2
3
37