Transducer Cable Specifications; Ethernet Cable - Simrad EC150-3C Installation Manual

Table of Contents

Advertisement

Transducer cable specifications

Some versions
A
of the cable are
slightly thicker
approximately 1
metre from the
transducer plug due
to a splice.
This end of the cable
B
is terminated in the
Power Supply Unit.
This end of the cable
C
is connected to the
transducer.
The EC150-3C is
delivered with a
power supply and an
open-ended cable. The transducer cable is 40 metres long. The cable can not be extended.
Note
The cable can be cut to match the installation requirements. Make sure that the cable
length is minimum 15 metres.
: 40 m
Cable length
Cable outer diameter
Bending radius
: 106 mm (Theoretical)
Static
: 160 mm (Theoretical)
Dynamic
Related topics
Technical specifications, page 15

Ethernet cable

The maximum length of the Ethernet cable is 100 meters. It is very important that a
high-quality Ethernet cable is used. You must use CAT-5E STP (Shielded Twisted Pair)
quality or better. If you use a cable with lower bandwidth capacity you will reduce the
EC150-3C performance.
If the length of the Ethernet cable exceeds approximately 60 metres, we recommend
that you use an Ethernet switch as a "buffer". The Ethernet switch is not a part of the
EC150-3C scope of supply.
438371/A
: 13.3 mm
Introduction
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents