50/200 Combi C Transducer - Simrad TRANSDUCER - INSTALLATION GENERIC REV H Installation Manual

Echo sounder transducers
Table of Contents

Advertisement

50/200 Combi C transducer

1
50 kHz
2
50 kHz
3
200 kHz
4
Screen
5
200 kHz
White
6
Thermistor
Green
7
Thermistor
Yellow
Multi-Con-X
connector
1
2
3
4
5
6
7
Note: The transducer cable must not be exposed
to oil or other petroleum fluids.
W802-12
Rev.A
851-160164/H
This is the termination of the transducer cable from the 50/200
Combi C transducer. The transducer cable is terminated
in a Multi-Con-X connector manufactured by Conxall
(www.conxall.com). The other end of the cable is permanently
fixed to the transducer.
"Multi-Con-X" provided by www.conxall.com
View: Looking
into
A small circular marker identifies pin 1.
Red
(1)
Black
Blue
(2)
(3)
(4)
Connection box
with Multi-Con-X socket
1
2
3
4
5
6
7
50/200 Combi C transducer, termination
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the "dry part" of the transducer cable in a steel conduit.
Related topics
Cable splicing on page 36
Steel conduit on page 37
GPT transducer terminations
the socket on the rear side of the cabinet
(7)
(6)
(5)
50 kHz
50 kHz
200 kHz
200 kHz
Screen to plug housing
Thermistor
Thermistor
A
N
B
M
C
L
D
K
E
J
F
H
GPT Transducer
socket
C
D
H
J
4
17
"Auxiliary" 25-pin
D-connector on GPT
63