Dynacord DSP 600 Owner's Manual page 30

Fir-tune sound system processor
Hide thumbs Also See for DSP 600:
Table of Contents

Advertisement

Available languages

Available languages

DYNACORD
Detail
Use the < SELECT > buttons to navigate to the filter setting (see table below) you wish to adjust, and the Value Up and
Down buttons to alter these settings.
Parameter
Frequency (F)
Gain
Active/Bypass
Type
Quality (Q)
To exit the Input GEQ edit screen, press the Input GEQ button, use the < SELECT > buttons to again highlight the top
line of the edit screen display or press any other DSP block button.
I
D
NPUT
ELAY
The DSP 600 offers an input delay that is useful for compensating for different arrival times of sound origi-
nating from loudspeakers that are closer or further away from the listener than others. A technique known
as the Haas Effect allows the operator to create the illusion that all of the sound has originated from the
stage even though additional speakers have been placed around the room.
HINT: The Input Delay parameter is especially usefull for delay lines. In this case the required delay depends only
on the position of the delay line and is identical for all ways, e.g. output channels of the DSP 600. By editing
the Input Delay parameter the delays of all output channels routed to this input are adjusted automatically.
Available Input Delay parameters are Delay, Units and Active/Bypass. The Delay parameter allows the user to determine
the Delay time values and the Active/Bypass parameter to activate or deactivate the delay.
To access the Input Delay, press the Delay button found on the input processing menu. Subsequent button presses will
toggle the display between Input A and Input B. Input delay parameters are accessed using the <SELECT> button to
navigate between Delay, Unit and Active/Bypass using the VALUE up/down buttons to adjust values. Following table
shows the available units of the delay.
30
Fader
Description
Fader active (Active)
Fader deactivated (Bypass)
Table 5-8: Fader in GEQ
IN A:GEQ
F:20Hz
Gain:0.0dB
Type: Symmetric Q
Description
Select frequency band
The amount of boost or cut (-12.0 to +12.0 dB)
Select Active to activate the filter. Select Bypass to deactivate the filter.
Following filter types are available:
• Symmetric Q
• Proportional Q
• Constant Q
Quality of the filter
Table 5-9: GEQ band parameters
IN A:Input Delay
Delay: 0.0
Unit: ms
Detail
Active
Q: 4.3
Active

Hide quick links: