Edit; Dsp Parameters - Dynacord DSP 600 Owner's Manual

Fir-tune sound system processor
Hide thumbs Also See for DSP 600:
Table of Contents

Advertisement

Available languages

Available languages

5.8 Edit

Both Factory and User presets can be edited, but edited presets can only be stored in User preset locations.
S
E
TANDARD
DIT MODE
The DSP 600 defaults to Standard Edit mode wherein, input and output channel parameters are appropriately linked.
Refer to the illustrations in chapter "Configurations of the DSP 600" on page 36 to see which channels are parameter-
linked for each configuration. Linked parameters are always identical in value. For instance, setting a graphic eq curve
for Input A, sets the same curve for Input B, if the configuration has linked stereo inputs. Either input channel can be
edited; changes will be reflected in both. The same is true for parameters of linked output channels. The only exception
to the linking of parameters is the Mute buttons. Output channels can be individually muted at any time, either from the
DSP 600 front panel or the IRIS-Net application.
F
E
M
ULL
DIT
ODE
In the Setup EDITING menu, the edit mode can be changed to Full. In Full Edit, no parameter links are enforced, regard-
less of the configuration selected. Any parameter can be changed without any effect on other parameter values.
Regardless of the edit mode selected, there are two means to enter edit mode: pressing the Edit button or pressing any
DSP block button. Use the < SELECT > buttons to navigate to the top line of any edit screen, and the Value Up and Down
buttons to navigate to any other Edit screen. As a short-cut, press a DSP block button to jump to the last selected screen
of said block and navigate as above to reach the desired screen.

5.9 DSP Parameters

The following section is a detailed description of every DSP parameter available in the DSP 600; grouped by DSP block,
in order of the signal flow of the DSP 600.
Illustration 5-6: DSP blocks of outputs 1 to 6
Not all parameters may be accessible in every preset and, depending on the configurations set by the contractor/install-
er, not all presets and/or preset values may be available for editing. Changes to preset availability, parameter availability
and preset value ranges can only be set using the IRIS-Net application.
Setup: EDITING
Edit Mode: Standard
Link: Off
Setup: EDITING
Edit Mode: Full
Link: Off
Illustration 5-5: DSP blocks of input A or B
SIGNAL
GENERATOR
FIR FILTER
DSP 600
LIMITERS
27