7. Lightware REST API Reference
6.11. Network Security
6.11.1. Enabling/Disabling Ethernet Port
Request and Response
request-line: POST·http://<ip>/api/V1/MEDIA/ETHERNET/<ethernet_port>/Enabled·HTTP/1.1
ɯ
ɯ
body:
<status>
status-line: 200 OK
ɮ
body:
<status>
ɮ
Parameters
Identifier
Parameter description
<ethernet_port>
Ethernet port number
<status>
The port is enabled.
The port is disabled.
Example
request-line: POST http://192.168.0.50/api/V1/MEDIA/ETHERNET/P1/Enabled HTTP/1.1
ɯ
body:
false
ɯ
ɮ
status-line: 200 OK
ɮ
body:
false
6.11.2. Querying Network Service Port Number
Request and Response
#http #https
request-line: GET·http://<ip>/api/V1/MANAGEMENT/NETWORK/SERVICES/<port>/Port·HTTP/1.1
ɯ
ɮ
status-line: 200·OK
ɮ
body:
<port_num>
Parameters
Identifier
Parameter description
<port>
Port type
<port_num>
Port number
Parameter values
P1-P3 (device-dependent)
true
false
Parameter values
HTTP
HTTPS
LW3
SERIAL1
SERIAL2
80
443
6107
8001
8002
Applied firmware package: v2.9.0b6 | LDC software: v2.7.6b4
MMX2 series – User's Manual
Example
request-line: GET http://192.168.0.50/api/V1/MANAGEMENT/NETWORK/SERVICES/HTTP/Port HTTP/1.1
ɯ
ɮ
status-line: 200 OK
ɮ
body:
80
6.11.3. Enabling/Disabling Network Service Port
Request and Response
request-line: GET·http://<ip>/api/V1/MANAGEMENT/NETWORK/SERVICES/<port>/Enabled·HTTP/1.1
ɯ
ɯ
body:
<status>
status-line: 200 OK
ɮ
body:
<status>
ɮ
Parameters
Identifier
Parameter description
<port>
Port type
<status>
The port is enabled.
The port is disabled.
Example
request-line: POST http://192.168.0.50/api/V1/MANAGEMENT/NETWORK/SERVICES/HTTP/Enabled HTTP/1.1
ɯ
ɯ
body:
false
ɮ
status-line: 200 OK
ɮ
body:
false
6.11.4. Querying the Username for Authentication

INFO:
MMX2 series deal with one user for authentication and the username (admin) can not be changed.
Request and Response
request-line: GET·http://<ip>/api/V1/MANAGEMENT/NETWORK/AUTH/USER1/Name·HTTP/1.1
ɯ
ɮ
status-line: 200·OK
ɮ
body:
admin
Example
request-line: GET http://192.168.0.50/api/V1/MANAGEMENT/NETWORK/AUTH/USER1/Name HTTP/1.1
ɯ
ɮ
status-line: 200 OK
ɮ
body:
admin
Parameter values
HTTP
HTTPS
true
false