Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E1313
Fan redundancy
lost. Check
fans.
E1410
Internal Error
detected.
Check "FRU X".
E1414
CPU # temp
exceeding
range. Check
CPU heatsink.
E1418
CPU # not
detected.
Check CPU is
seated
properly.
E141C
Unsupported
CPU
configuration.
Check CPU or
BIOS revision.
26
About Your System
Causes
The system is no longer
fan redundant. Another
fan failure would put the
system at risk of
over-heating.
Specified processor has an
internal error. The error
may or may not have been
caused by the processor.
Specified processor is out
of acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an
unsupported
configuration.
Processors are in an
unsupported
configuration.
Corrective Actions
Check LCD for
additional scrolling
messages. See
"Troubleshooting a Fan"
on page 152.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help" on
page 167.
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Microprocessors" on
page 160 and
"Troubleshooting System
Cooling Problems" on
page 151.
Ensure that the specified
microprocessor is
properly installed. See
"Troubleshooting the
Microprocessors" on
page 160.
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.