Dell PowerEdge R410 Hardware Owner's Manual page 100

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R410:
Table of Contents

Advertisement

Removing the Integrated Storage Controller Card
WARNING:
cover and access any of the components inside the system. Before you begin this
procedure, review the safety instructions that came with the system.
1 Turn off the system, including any attached peripherals, and disconnect
the system from the electrical outlet.
2 Open the system. See "Opening the System" on page 82.
3 If installed, remove the expansion card. See "Removing an Expansion
Card" on page 99.
4 Remove the card from the storage controller card slot:
Pull the blue release lever to free the card from the connector on the
a
expansion-card riser.
Lift to remove the card.
b
Figure 3-12. Installing the Integrated Storage Controller Card
1
1
SAS data cable connector
3
expansion card riser
5
release lever (blue)
100
Installing System Components
Only trained service technicians are authorized to remove the system
2
3
2
storage connector
4
integrated storage controller card
4
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

External oemr r410

Table of Contents