Power Distribution Board (Service-Only Procedure) - Dell PowerEdge R410 Hardware Owner's Manual

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R410:
Table of Contents

Advertisement

Installing the SAS Backplane
1 Install the SAS backplane:
Lower the backplane into the system, being careful to avoid damaging
a
components on the face of the board.
Align the slots in the backplane with the retention hooks on the back
b
of the drive bays, then move the backplane forward until the retention
hooks fit through the slots in the backplane. See Figure 3-27.
Slide the backplane downward until the two blue retention latches
c
snap into place.
2 Connect the SAS data and power cables to the SAS backplane.
3 Install the hard drives in their original locations.
4 Close the system. See "Closing the System" on page 83.
5 Reconnect the system to its electrical outlet and turn the system on,
including any attached peripherals.
Power Distribution Board (Service-Only
Procedure)
The power distribution board is located on your system directly behind the
power supply fan modules. This feature provides additional cooling to the
power supplies through the power distribution shroud that routes airflow to
the power supplies. See Figure 3-28.
Removing the Power Distribution Board
WARNING:
cover and access any of the components inside the system. Before you begin this
procedure, review the safety instructions that came with the system.
1 Remove the power supplies from the system. See "Removing a Redundant
Power Supply" on page 92.
2 Locate the power distribution shroud cover and lift it out. See Figure 3-1.
3 Disconnect power distribution cables from the system board (see "System
Board (Service-Only Procedure)" on page 140) and disconnect the fan
cable connectors. See Figure 3-28.
138
Installing System Components
Only trained service technicians are authorized to remove the system