Dell PowerEdge R410 Hardware Owner's Manual page 24

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R410:
Table of Contents

Advertisement

Table 1-2. LCD Status Messages (Optional) (continued)
Code
Text
E1114
Ambient Temp
exceeds
allowed range.
E1116
Memory
disabled, temp
above range.
Power cycle
AC.
E1210
Motherboard
battery
failure. Check
battery.
E1211
RAID
Controller
battery
failure. Check
battery.
E1216
3.3V Regulator
failure.
Reseat PCIe
cards.
E1229
CPU # VCORE
Regulator
failure.
Reseat CPU.
24
About Your System
Causes
Ambient temperature has
a reached a point outside
of the allowed range.
Memory has exceeded
allowable temperature and
has been disabled to
prevent damage to the
components.
CMOS battery is missing
or the voltage is outside of
the allowable range.
RAID battery is either
missing, bad, or unable to
recharge due to thermal
issues.
3.3V voltage regulator has
failed.
Specified processor
VCORE voltage regulator
has failed.
Corrective Actions
See "Troubleshooting
System Cooling
Problems" on page 151.
Remove AC power to the
system for 10 seconds and
restart the system.
See "Troubleshooting
System Cooling
Problems" on page 151.
If the problem persists,
see "Getting Help" on
page 167.
See "Troubleshooting the
System Battery" on
page 150.
Reseat the RAID battery
connector. See "Installing
the RAID Battery" on
page 118, and
"Troubleshooting System
Cooling Problems" on
page 151.
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" on
page 159.
Reseat the processor(s).
See "Troubleshooting the
Microprocessors" on
page 160.
If the problem persists,
see "Getting Help" on
page 167.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

External oemr r410

Table of Contents