REMOTE CONTROL
Remote control (CI-V) information
D Command table
Cmd� Sub cmd�
Data
16*
58
00 ~ 02
5E
00/01
65 29
00/01
66
00/01
67
00/01
4
17*
See p� 16�
18
00
5
01*
19
00
1A*
00
See p� 18�
01
See p� 17�
02
See p� 19�
03 29
See p� 19�
04 29
See p� 19�
05 SET > Tone Control/TBW
00 01
See p� 19�
00 02
00 ~ 10
00 03
00 ~ 10
00 04
See p� 19�
00 05
00 ~ 10
00 06
00 ~ 10
00 07
See p� 19�
00 08
00 ~ 10
00 09
00 ~ 10
00 10
See p� 19�
00 11
See p� 19�
00 12
See p� 19�
Description
Send/read SSB transmit bandwidth
(00=WIDE, 01=MID, 02=NAR)
( One of the following values is
applied, depending on the "COMP"
status (ON or OFF):
WIDE (Command: 1A 05
00 15),
MID (Command: 1A 05
00 16), or
NAR (Command: 1A 05
00 17))
MAIN/SUB Tracking function
(00=OFF, 01=ON)
Set the IP Plus function
(00=OFF, 01=ON)
Send/read the TX Inhibit function
(00=OFF, 01=ON)
Send/read the DPD function
(00=OFF, 01=ON)
Send CW messages
Turn OFF the transceiver
Turn ON the transceiver
Read the transceiver ID
Send/read memory contents
Send/read band stacking register
contents
Send/read memory keyer contents
Send/read the selected IF filter width
Send/read the selected AGC time
constant
RX > SSB >
Send/read RX HPF/LPF settings
RX > SSB >
Send/read RX Tone (Bass) level
(00=–5 ~ 10=+5)
RX > SSB >
Send/read RX Tone (Treble) level
(00=–5 ~ 10=+5)
RX > AM >
Send/read RX HPF/LPF settings
RX > AM >
Send/read RX Tone (Bass) level
(00=–5 ~ 10=+5)
RX > AM >
Send/read RX Tone (Treble) level
(00=–5 ~ 10=+5)
RX > FM >
Send/read RX HPF/LPF settings
RX > FM >
Send/read RX Tone (Bass) level
(00=–5 ~ 10=+5)
RX > FM >
Send/read RX Tone (Treble) level
(00=–5 ~ 10=+5)
RX > CW >
Send/read RX HPF/LPF settings
RX > RTTY >
Send/read RX HPF/LPF settings
RX > PSK >
Send/read RX HPF/LPF settings
Cmd� Sub cmd�
Data
1A*
05 00 13
00 ~ 10
00 14
00 ~ 10
00 15
See p� 19�
00 16
See p� 19�
00 17
See p� 19�
00 18
See p� 19�
00 19
00 ~ 10
00 20
00 ~ 10
00 21
00 ~ 10
00 22
00 ~ 10
SET > Function
00 23
00 00 ~ 02 55 Send/read the Beep Level setting
00 24
00/01
00 25
00/01
00 26
00 ~ 03
00 27
00 50 ~ 02 00 Function > Beep Sound (MAIN)
00 28
00 50 ~ 02 00 Function > Beep Sound (SUB)
00 29
00/01
00 30
00 ~ 02
00 31
00/01
00 32
00 02 ~ 02 00 TX Power Limit > 1�8M
00 33
00 02 ~ 02 00 TX Power Limit > 1�8M (DATA)
00 34
00 02 ~ 02 00 TX Power Limit > 3�5M
00 35
00 02 ~ 02 00 TX Power Limit > 3�5M (DATA)
5
Description
TX > SSB >
Send/read TX Tone (Bass) level
(00=–5 ~ 10=+5)
TX > SSB >
Send/read TX Tone (Treble) level
(00=–5 ~ 10=+5)
TX > SSB >
Send/read TX bandwidth for wide
TX > SSB >
Send/read TX bandwidth for mid
TX > SSB >
Send/read TX bandwidth for narrow
TX > SSB-D >
Send/read TX bandwidth
TX > AM >
Send/read TX Tone (Bass) level
(00=–5 ~ 10=+5)
TX > AM >
Send/read TX Tone (Treble) level
(00=–5 ~ 10=+5)
TX > FM >
Send/read TX Tone (Bass) level
(00=–5 ~ 10=+5)
TX > FM >
Send/read TX Tone (Treble) level
(00=–5 ~ 10=+5)
(00 00=Minimum ~ 02 55=Maximum)
Send/read the Beep Level Limit setting
(00=OFF, 01=ON)
Send/read the Beep (Confirmation)
setting
(00=OFF, 01=ON)
Send/read the Band Edge Beep setting
( 00=OFF, 01=ON (Default),
02=ON (User),
03=ON (User) & TX Limit)
(00 50=500 Hz ~ 02 00=2000 Hz)
(00 50=500 Hz ~ 02 00=2000 Hz)
Send/read the Speaker MAIN/SUB Mix
(00=OFF, 01=ON)
RF/SQL Control
(00=Auto, 01=SQL, 02=RF+SQL)
Send/read the Cancel CI-V Remote
Set Levels
( 00=All Volume Levels,
01=Operated Volume Level)
(00 02=2 W ~ 02 00=200 W)
(00 02=2 W ~ 02 00=200 W)
(00 02=2 W ~ 02 00=200 W)
(00 02=2 W ~ 02 00=200 W)
Need help?
Do you have a question about the IC-7760 and is the answer not in the manual?
Questions and answers