Remote control (CI-V) information
D Command table
Cmd� Sub cmd�
Data
14*
09
00 00 ~ 02 55 Send/read CW pitch (5 Hz steps)
0A
00 00 ~ 02 55 Send/read the selected band's RF
0B
00 00 ~ 02 55 Send/read MIC gain
0C
00 00 ~ 02 55 Send/read keying speed
0D 29
00 00 ~ 02 55 Send/read Notch filter setting
0E
00 00 ~ 02 55 Send/read the COMP level
0F
00 00 ~ 02 55 Send/read the Break-IN Delay setting
12 29
00 00 ~ 02 55 Send/read NB level
13 29
00 00 ~ 02 55 Send/read the DIGI-SEL shift amount
14
00 00 ~ 02 55 Send/read DRIVE Gain
15
00 00 ~ 02 55 Send/read Monitor audio [MONI] level
16
00 00 ~ 02 55 Send/read the VOX gain
17
00 00 ~ 02 55 Send/read the Anti VOX gain
19
00 00 ~ 02 55 Send/read LCD backlight brightness
15
01 29
00/01
02 29
00 00 ~ 02 55 Read S-meter level
05 29
00/01
07 29
00/01
11
00 00 ~ 02 55 Read the Po meter level
12
00 00 ~ 02 55 Read SWR meter level
13
00 00 ~ 02 55 Read ALC meter level
14
00 00 ~ 02 55 Read COMP meter level
15
00 00 ~ 02 55 Read Vd meter level
16
00 00 ~ 02 55 Read Id meter level
Description
( 00 00=300 Hz ~ 01 28=600 Hz ~
02 55=900 Hz)
power
(00 00=Minimum ~ 02 55=Maximum)
(00 00=Minimum ~ 02 55=Maximum)
(00 00=6 WPM ~ 02 55=48 WPM)
( 00 00=max� Counter Clockwise ~
01 28=center ~ 02 55=max� Clockwise)
(00 00=0 ~ 02 55=10)
(00 00=2�0d ~ 02 55=13�0d)
(00 00=0% ~ 02 55=100%)
(00 00=min� ~ 02 55=max�)
(00 00=0% ~ 02 55=100%)
(00 00=0% ~ 02 55=100%)
(00 00=0% ~ 02 55=100%)
(00 00=0% ~ 02 55=100%)
(00 00=0% ~ 02 55=100%)
Read noise or S-meter squelch status
(00=Close, 01=Open)
( 00 00=S0, 01 20=S9,
02 41=S9+60 dB)
Read various squelch (tone squelch,
and so on) status
(00=Close, 01=Open)
Read the OVF status
( 00=OVF indicator is OFF,
01=OVF indicator is ON)
( 00 00=0W ~ 01 43=100W ~
02 12=200W)
( 00 00=SWR1�0, 00 48=SWR1�5,
00 80=SWR2�0, 01 20=SWR3�0)
(00 00=Minimum ~ 01 20=Maximum)
( 00 00=0 dB ~ 01 30=15 dB ~
02 41=30 dB)
(00 00=0 V ~ 01 51=44 V ~ 02 11=52 V)
( 00 00=0 A ~ 00 77=5 A ~
01 65=10 A ~ 02 41=15 A)
Cmd� Sub cmd�
Data
16*
02 29
00
01
02
12 29
01 ~ 03
22 29
00/01
32 29
00
01
02
03
40 29
00/01
41 29
00/01
42 29
00/01
43 29
00/01
44
00/01
45
00/01
46
00/01
47
00
01
02
48 29
00/01
4E 29
00/01
4F 29
00/01
50
00/01
3
53*
00/01
29
56 29
00/01
57 29
00 ~ 02
4
Description
Preamp OFF
Preamp 1 ON
Preamp 2 ON
Send/read the AGC time constant
(01=FAST, 02=MID, 03=SLOW)
Send/read the Noise blanker
(00=OFF, 01=ON)
Audio peak filter OFF
Audio peak filter WIDE ON
(320 Hz is selected when SHARP
APF is set)
Audio peak filter MID ON
(160 Hz is selected when SHARP
APF is set)
Audio peak filter NAR ON
(80 Hz is selected when SHARP
APF is set)
Send/read the Noise reduction
(00=OFF, 01=ON)
Send/read the Auto Notch function
(00=OFF, 01=ON)
Send/read the Repeater tone
(00=OFF, 01=ON)
Send/read the Tone squelch
(00=OFF, 01=ON)
Send/read the Speech compressor
(00=OFF, 01=ON)
Send/read the Monitor [MONI] function
(00=OFF, 01=ON)
Send/read the VOX function
(00=OFF, 01=ON)
BK-IN function OFF
Semi BK-IN function ON
Full BK-IN function ON
Send/read the Manual Notch function
(00=OFF, 01=ON)
Send/read the DIGI-SEL function
(00=OFF, 01=ON)
Send/read the Twin peak filter
(00=OFF, 01=ON)
( Can be turned ON only when Mark
and Shift are set to 2125 Hz and
170 Hz, respectively)
Send/read the Dial Lock function
(00=OFF, 01=ON)
L The main dial or panel display is
locked, depending on the Lock
Function (1A 05 00 77)�
Send/read the ANT-RX I/O
(00=OFF, 01=ON)
Send/read DSP IF filter type
(00=SHARP, 01=SOFT)
Send/read the Manual Notch width
(00=WIDE, 01=MID, 02=NAR)