4. Introduction
4.1.
General Information
It is the responsibility of the installer to ensure that the equipment or system into which the product is incorporated complies
with all relevant legislation and codes of practice which apply in the country of use.
CE Marking
All Invertek Drives products intended for use within the European Union carry the CE mark to indicate compliance with
European Directives (EMC Directive, Low Voltage Directive and Machinery Directive). A declaration of conformity is available
from the website, www.invertekdrives.com. For compliance with the European EMC Directive, the necessary guidance is
provided within this document and it is the responsibility of the installer to ensure this guidance is followed to ensure
compliance.
UKCA Marking
All Invertek Drives products intended for use within the United Kingdom carry the UKCA mark to indicate compliance with
Following UK regulations: Electromagnetic Compatibility Regulations, Supply of Machinery (Safety) Regulations, Electrical
Equipment (Safety) Regulations. A declaration of conformity is available from the website, www.invertekdrives.com. For
compliance with the relevant sections of the above regulations, the necessary guidance is provided within this document and it
is the responsibility of the installer to ensure this guidance is followed to ensure compliance.
UL Conformity
A list of currently listed products is available from the UL website, www.ul.com. For compliance with UL requirements, the
necessary guidance is provided within this document and it is the responsibility of the installer to ensure this guidance is followed to
ensure compliance.
Safe Torque OFF ("STO") Function
The drive incorporates a hardware STO (Safe Torque Off) Function, designed in accordance with the standards listed below.
Standard
EN 61800-5-2:2017
EN ISO 13849-1:2015
EN 61508 (Part 1 to 7):2010
EN60204-1:2006 + A1:2009 + AC: 2010
EN 62061:2021
*NOTE TUV Approval of the "STO" function is relevant for drives which have a TUV logo applied on the drive rating label. The
STO input must not be used for any safety related function if the drive unit does not carry the TUV logo on the rating label.
Unintended Car Movement
Brake Contact Monitoring (Unintended Car Movement) EN 81-20:2014+A3 (certification by Lift Institute)
Contactorless Operation
The drive can be used without a Motor contactor using the Safe Torque Off inputs according to parts of EN 81-20:2014 and
EN 81-50:2014 (certification by Lift Institute)
Classification
SIL3
PL "e"
SIL3
Uncontrolled Stop "Category 0"
SIL3
www.InvertekDrives.com
Independent Approval
*TUV

Advertisement

loading
Need help?

Need help?

Do you have a question about the elevator CORE and is the answer not in the manual?

Questions and answers