Nmea 0183 Wiring (Data Cable) - Lowrance LCX-112C Operation Instructions Manual

Fish-finding sonar & mapping gps
Table of Contents

Advertisement

120-ohm
terminator
Extension cable
LGC-3000 and display unit as an expandable NMEA 2000 network.
The diagram above has a double T connector with two 120-ohm
terminators — one at each end of the connector. It is easy to expand this
network by removing a terminator from one end of the double T connector,
then inserting a new T connector or extension cable between the double T
connector and terminator (See the NMEA 200 network general
information document that came with your unit for more information).

NMEA 0183 Wiring (Data cable)

To exchange NMEA 0183 data, this unit has two NMEA 0183 version
2.0 communication ports. Serial Communications Port one (Com1) and
Serial Communications Port two (Com2) can be used to transmit or
receive NMEA format GPS data.
The five wires for the Serial Communications Ports are combined with
the Display Unit Power cable and NMEA 2000 Power cable to form the
power/data cable (shown earlier). Com1 uses the yellow wire to transmit,
the orange wire to receive and the shield wire for signal ground. Com2
uses the blue wire to transmit, the green wire to receive and the shield
wire for signal ground.
Double T
Connector
LGC-3000
Network port
on display unit
32
Extension cable
120-ohm
terminator