Calibrating Ep Sensors; Ep-10 Fuel Flow Calibration - Lowrance LCX-112C Operation Instructions Manual

Fish-finding sonar & mapping gps
Table of Contents

Advertisement

Restore Defaults command from your Port Engine Interface Advanced
Options menu, only the settings for the Port Engine Interface will be
reset to factory defaults. Other engine interfaces on the network will
not be affected.
To restore default settings:
1. Press
MENU| MENU
2000 menu will appear with five options: Bus Setup, Fuel Management,
NMEA 2000 Alarms, Waypoint Sharing and Backlight Synchronization.
2. Highlight
B
3. Use ↑ ↓ to select the desired fluid level and press
Configuration menu will appear.
4. Highlight
A
5. Select
R
ESTORE
appear: Are you sure you wish to change this device's configuration?
6. Highlight
Y
main display.
NOTE:
The Suzuki Engine Interface Device Configuration menu contains
two Engine Trim calibration commands, which will be addressed in
the next segment of this section, Calibrating EP Sensors.

Calibrating EP Sensors

The factory calibration settings for the EP-10 Fuel Flow, EP-15 Fluid
Level and Suzuki Engine Interface should be adequate for the majority
of applications, so calibration will not be necessary in most cases.

EP-10 Fuel Flow Calibration

The default calibration for the EP-10 Fuel Flow is adequate in most
cases, but if Fuel Used readings are off by more than 3 percent,
calibration is recommended.
To check fuel flow accuracy:
Select Fuel Used to be shown as Overlay Data on your unit's main display.
Refer to the Overlay Data segment of this manual for instructions on how
to select Fuel Used data as Overlay Data.
1. After selecting Fuel Used as overlay data, fill up your tank and press
|
.
MENU
MENU
2. Select
NMEA 2000
3. Highlight
F
UEL
4. Use ↑ ↓ to select the location (Port, Center or Starboard) of the fuel
flow you want to calibrate and press
5. Highlight
message will appear: Are you sure you wish to Fill Tank?
, use ↑ ↓ to select
and press
S
US
ETUP
O
DVANCED
PTIONS
and press
D
EFAULTS
and press
ENT
ES
and press
and press
M
ANAGEMENT
and press
F
T
ILL
ANK
NMEA 2000
.
ENT
and press
ENT
. The following message will
ENT
. Press
repeatedly to get back to the
EXIT
.
ENT
. Select
ENT
.
ENT
. The following confirmation
ENT
202
and press
ENT
ENT
.
T
L
ANK
OCATION
. The NMEA
. The Device
and press
.
ENT