Installing the rear system fan

Attention:
v Replace a failed fan within 48 hours.
v To ensure proper cooling and airflow, do not operate the server for more than 30
To install the rear system fan, complete the following steps:
1. The replacement fan comes with the rubber grommets installed 1 ; however,
2. Position the fan 2 so that the grommets protrude through the holes in the
3. Connect the fan cable to the system board (see "System-board internal
4. Install any adapters that you removed (see "Installing an adapter" on page 57).
5. Install the side cover (see "Installing the side cover" on page 33).
6. Lock the side cover if you unlocked it during removal.
7. Reconnect the external cables and power cords; then, turn on the attached
74
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide
minutes with the side cover removed.
they might have come out during shipment. If any of the rubber grommets are
missing from the fan, install them on the fan before you continue. Use
needle-nosed pliers to pull the grommets through the holes in the fan.
chassis; then, use needle-nosed pliers to pull the grommets through the holes
from outside the chassis.
connectors" on page 19 for the location of the rear fan connector).
devices and turn on the server.