Lenovo ThinkServer TS200 Installation And User Manual page 39

Lenovo thinkserver ts200: user guide
Table of Contents

Advertisement

Table 4. System-board LEDs (continued)
LED
Baseboard management
controller heartbeat LED
Standby power LED
The following table describes the LEDs on the system board and extender card and
suggested actions to correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Hardware Maintenance Manual to determine which components are customer
replaceable units (CRUs) and which components are field replaceable units (FRUs).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
System error or
information LED lit
Description
DIMM 1 to DIMM 6
A DIMM has failed or is incorrectly
error LEDs
installed.
CPU 1 error LED
Microprocessor 1 has failed, is
missing, or has been incorrectly
installed.
Note: (Trained service technician
only) Make sure that the
microprocessors are installed in the
correct sequence; see the
procedures for removing and
installing a microprocessor in the
Hardware Maintenance Manual.
CPU mismatch LED
A mismatched microprocessor has
been installed.
Note: All microprocessors must
have the same speed and cache
size.
VRM failure LED
Microprocessor 2 VRM has failed or
is incorrectly installed.
System-board error
System-board CPU VRD, power
LED
voltage regulators, or both have
failed.
Description
This LED flashes to indicate that the IMM is functioning
normally.
When this LED is lit, it indicates that the server is connected
to ac power.
Action
1. Remove the DIMM that is indicated by a lit error
LED.
2. Reseat the DIMM.
3. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. DIMM
b. (Trained service technician only) System board
1. Check the system-event log to determine the
reason for the lit LED.
2. (Trained service technician) Reseat the failing
microprocessor.
3. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. (Trained service technician only) Failing
microprocessor
b. (Trained service technician only) System board
1. Run the Setup Utility and view the microprocessor
information to compare the installed
microprocessor specifications.
2. (Trained service technician only) Remove and
replace one of the microprocessors so that they
both match.
1. Reseat the VRM
2. Replace the following components one at a time,
in the order shown, restarting the server each time:
a. VRM
b. (Trained service technician only) System board
3. Replace the VRM
(Trained service technician only) Replace the system
board.