v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
3818005
Current Bank Core Root of Trust
Measurement (CRTM) capsule signature
invalid
3818006
Opposite bank CRTM capsule signature
invalid
3818007
CRTM update capsule signature invalid

Integrated management module error messages

The following table describes the IMM error messages and suggested actions to
correct the detected problems. For more information about IMM, see the IMM
User's Guide on the Web.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the "Parts Listing" section in the Hardware Maintenance Manual to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
Numeric sensor Ambient Temp going
high (upper critical) has asserted.
Numeric sensor Ambient Temp going
high (upper non-recoverable) has
asserted.
Numeric sensor Planar 3.3 V going
low (lower critical) has asserted.
Numeric sensor Planar 3.3 V going
high (upper critical) has asserted.
Numeric sensor Planar 5 V going low
(lower critical) has asserted.
Numeric sensor Planar 5 V going
high (upper critical) has asserted.
152
ThinkServer TS200 Types 6522, 6523, 6524, 6525, 6526, 6528, 6529, and 6530: Installation and User Guide
Action
1. Run the Setup utility, select Load Default
2. (Trained service technician only) Replace the
1. Switch the firmware bank to the backup bank.
2. Run the Setup utility, select Load Default
3. Switch the bank back to the current bank.
4. (Trained service technician only) Replace the
1. Run the Setup utility, select Load Default
2. (Trained service technician only) Replace the
Severity
Description
Error
An upper critical sensor
going high has asserted.
Error
An upper nonrecoverable
sensor going high has
asserted.
Error
A lower critical sensor going
low has asserted.
Error
An upper critical sensor
going high has asserted.
Error
A lower critical sensor going
low has asserted.
Error
An upper critical sensor
going high has asserted.
Settings, and save the settings.
system board.
Settings, and save the settings.
system board.
Settings, and save the settings.
system board.
Action
Reduce the ambient temperature.
Reduce the ambient temperature.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.