Removing An Adapter - Lenovo ThinkServer TS200 Installation And User Manual

Lenovo thinkserver ts200: user guide
Table of Contents

Advertisement

v The drives that are preinstalled in the server come with power and signal cables
v When you install a drive, make sure that one of the signal cable drive connectors
v When you route a cable, make sure that it does not block the airflow to the rear
The following cables are provided:
v Power cables: Four-wire power cables connect the drives to the power supply.
v Signal cables: Signal cables are typically flat cables, also called ribbon cables,
For more information about the requirements for SAS/SATA cables and connecting
SAS/SATA devices, see the documentation that comes with these devices.
See http://www.lenovo.com/thinkserver and click the Options tab for a list of
supported options.

Removing an adapter

To remove an adapter, complete the following steps:
attached. If you replace any drives, remember which cable is attached to which
drive.
is connected to the drive and that the connector at the other end of the signal
cable is connected to the system board or a compatible adapter or controller that
you have installed.
of the drives or over the microprocessor or DIMMs.
At the ends of these cables are plastic connectors that can be attached to
different drives; these connectors vary in size. Use either a four-wire power cable
or SATA power cable with SATA drives, but do not use both at the same time
(use one or the other).
that connect SATA attached, SATA and SAS to the system board. Two or three
types of signal cables come with the server:
– SATA attached (for optical drives): The flat SATA-attached signal cable has
two connectors. One of these connectors is attached to the optical drive, and
one is attached to one of the connectors on the system board.
– Simple-swap SATA: Simple-swap SATA models come with four SATA cables
that are already connected to the system board and the backplate at the rear
of the simple-swap drive cage.
– Hot-swap SAS/SATA: Hot-swap SAS/SATA models come with one or two
(depending on the model) data cables that connect the SAS/SATA controller to
the hot-swap backplane. The data cable provides inherent connectivity for the
SAS or SATA drives that the server supports. Therefore, additional cabling is
not required for these drives.
1. Read the safety information that begins on page vii and "Installation guidelines"
on page 29.
2. Turn off the server and all attached devices; then, disconnect all power cords
and external cables.
3. Unlock and remove the side cover (see "Removing the side cover" on page
32).
4. Disconnect any cables from the adapter or any cables that impede access to
the adapter.
5. Open the rear retention bracket 1 .
6. If you are removing a full-length adapter, press on the retaining tab (two blue
pull points) on the left side of the front adapter-retention bracket until the
release lever on the right side of the bracket clicks into place.
Chapter 5. Installing and replacing optional devices
55

Advertisement

Table of Contents
loading