2.4.4 Multidrop Address Selection

For RS485 half-duplex interface connections, the scanner multidrop address
should be set using the rotary switches placed inside the C-BOX 200.
The valid address range is from 00 to 31. This value is read only at power-
on; any change at run-time has no effect.
If an invalid value is detected (32-99) the C-BOX cannot communicate with
the Multiplexer and the green LED remains off. Furthermore, the SEND
command configures the scanner using the previously configured valid
scanner address.
TENS
UNITS
Figure 2.10 - Rotary switches
Installation - 11