The C-BOX 200 spring clamp connector pinouts are indicated in the following
table.
Refer to the scanner Installation Manual for details.
Pin
1, 3, 5
2, 4, 6
7, 8
*9, 13
*10, 14
*11, 15
*12, 16
20, 33, 34, 40
21
23
27
28
35
37
39
22
24
25, 26
29
30
31
32
36
38
*
The signals on pins 9, 10, 11 and 12 are repeated on pins 13, 14, 15 and 16 to facilitate
network connections (i.e. Multiplexer connections using the RS485 half-duplex Interface). In
this way the network bus can enter and exit the C-BOX from different spring clamps but be
physically connected together.
Pin 7 or 8 should be connected to the earth ground.
Pin 17, 18 and 19 are not present in the C-BOX 200 model.
Name
VS
GND
EARTH GROUND
RS485 CABLE SHIELD
RS485 REF
RTX485+
RTX485-
Reserved
OUT1+
OUT2+
EXT TRIG+
EXT TRIG-
TXA
RXA
SGND
DS2100
DS2400
OUT REF
OUT REF
NC
NC
NC
NC
NC
RTSA
CTSA
NOTE
DS4300
DS4600
OUT1-
OUT2-
Reserved
IN1+
IN1-
IN2+
IN2-
GND
SGND AUX
C-BOX 200