Electrical Connections And Setup - Datalogic C-BOX 200 Installation Manual

Datalogic scanning scanner installation manual c-box 200
Table of Contents

Advertisement

C-BOX 200
DATALOGIC

2.4 ELECTRICAL CONNECTIONS AND SETUP

The following figure shows the typical layout. The dotted line in the figure
refers to an optional hardware configuration.
PC
Scanner
Auxiliary
Interface
SCANNER
System Cables
Figure 2.5 – System layout
A PC can be quickly connected to the C-BOX 200 (and consequently to the
scanner auxiliary interface) through the internal 9-pin connector. This allows
monitoring of the data transmitted by the scanner or configuration through
the WinHost utility (see the scanner Installation Manual for more details). The
scanner auxiliary interface signals are also available on the internal spring
clamp connectors.
After making system cabling and switch settings (see sub-paragraphs under
2.4), connect the scanner to the 25-pin connector on the left side of the C-
BOX 200 housing.
Switch ON the C-BOX 200 power switch (see Figure 2.6).
After power on, an automatic connection procedure takes place between the
C-BOX 200 and the scanner. During this phase, requiring a few seconds, the
warning LED is turned ON. Once the procedure had been completed
successfully, the warning LED is turned OFF.
After system functioning has been verified, close the C-BOX 200 using the 4
cover screws making sure the rubber seal is fitted correctly between the
parts of the housing.
6 - Installation