Connection To A Multiplexer - Datalogic C-BOX 200 Installation Manual

Datalogic scanning scanner installation manual c-box 200
Table of Contents

Advertisement

DATALOGIC

2.4.6 Connection to a Multiplexer

The following figure shows a multidrop layout with C-BOX 200 devices
connected to a Multiplexer:
SCANNER
SCANNER
SCANNER
(*) If necessary enable the termination resistor only in the last device.
C-BOX 200
(up to 31)
EARTH GROUND
C-BOX 200
EARTH GROUND
C-BOX 200
EARTH GROUND
MULTIPLEXER
Figure 2.12 - Multiplexer connection
(*)
12
RTX485-
# N
11
RTX485+
10
RS485 REF
9
CABLE SHIELD
13
CABLE SHIELD
14
RS485 REF
15
RTX485+
16
RTX485-
12
RTX485-
# 1
11
RTX485+
10
RS485 REF
9
CABLE SHIELD
13 CABLE SHIELD
14
RS485 REF
15
RTX485+
16
RTX485-
12
RTX485-
# 0
11
RTX485+
10
RS485 REF
9
CABLE SHIELD
Three wires + shield
CABLE SHIELD
RS485 REF
RTX485+
RTX485-
EARTH GROUND
C-BOX 200
max 1200 m
120 Ohm
Installation - 13