Summary of Contents for Datalogic PowerScan BC9600 Series
Page 1
PowerScan™ BC9600 Base Stations QUICK REFERENCE GUIDE Industrial Base Station/Charger for PowerScan 9600 Family Bar Code Readers...
Page 2
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many countries, including the U.S.A. and the E.U. PowerScan is a trademark of Datalogic S.p.A. and/or its affiliates, registered in the U.S. All other trademarks and brands are property their respective owners.
2. License Fee License fees shall be due by End User to Datalogic according to the terms provided for in the rele- vant contract for the purchase of the Datalogic Product. 3. Termination Without prejudice to any other rights or remedies Datalogic may have, Datalogic may terminate this Agreement if End User fails to comply with the terms and conditions of this Agreement.
Page 5
PRICE OR FEE PAID BY END USER FOR THE DATALOGIC PRODUCT. UNDER NO CIRCUMSTANCES SHALL DATALOGIC OR ITS LICENSORS BE LIABLE TO END USER OR ANY THIRD PARTY FOR LOST PROF- ITS, LOST DATA, INTERRUPTION OF BUSINESS OR SERVICE, OR FOR ANY OTHER SPECIAL, CONSE-...
Page 6
U.S. federal agency has suspended, revoked or denied its export privileges. 9. Third Party Software The Datalogic Product may contain one or more items of third party software which use is governed by separate third party license, unless otherwise stated.
Italian Court of Bologna shall have exclusive jurisdiction over all matters regarding this Agreement, except that Datalogic shall have the right, at its absolute discre- tion, to initiate proceedings in the courts of any other state, country, or territory in which End User resides, or in which any of End User's assets are located.
POWERSCAN™ BC9600 BASE STATIONS USING THE BC9600 BASE STATION The BC9600 base station, when paired with one or more PowerScan™ PM/ PBT9600 readers, builds a Cordless Reading System for the collection, decod- ing and transmission of bar code data. It can be connected to a Host PC via RS232, USB, USB Type C or Ethernet, depending on the interchangeable con- nection module.
Base Station Models BASE STATION MODELS Each base station is composed of a cradle which must be connected to a con- nection module, depending on the interface desired and on the IP (water and dust) protection grade. The base station and connection module models are listed below. Base Station Models BC9600-433 BASE/CHARGER 433MHZ w/o conn.
Installation INSTALLATION To set up your BC9600 base station you must: 1. Physically install it. 2. Make all system connections. 3. Configure it. PACKAGE CONTENTS The base station package contains the following items: BC9600 Base Station (with Desktop Positioning Tab installed) •...
Mounting Instructions MOUNTING INSTRUCTIONS The base station can be either set on or mounted to a flat surface for desktop usage, or affixed vertically to a wall. Depending on the model, the appropriate connection module is already installed. PERMANENT MOUNTING For either desktop or wall mounting, the base station can be fastened directly to a flat surface using screws (not included).
Wall Mounting WALL MOUNTING The base station contains a reversible positioning tab for horizontal or vertical mounting. Figure 1 - Positioning Tab Desktop Positioning Tab (Horizontal) Wall Positioning Tab (Vertical) When shipped, the base station has the positioning tab installed in the Desktop position (horizontal).
Portable Desktop Mounting 3. Rotate the tab until you will see "WALL" tooth, put the rotated tab into place and secure it with the screw. PORTABLE DESKTOP MOUNTING For desktop mounting, if portability of the base station is required, the mounting plate can be used.
Page 15
Portable Desktop Mounting 2. Remove the adhesive strips protecting the mounting tabs on the base sta- tion. Protective Strips 3. Align the base station with the mounting plate until you see the sphere inside the bigger hole on the left. QUICK REFERENCE GUIDE...
Portable Desktop Mounting 4. Move the base station down until the sphere is aligned with the smaller hole. Connection Module Fast Release - Mounting the Bracket 1. Remove the protective strips. 2. Unscrew the connection module from the base station. 3.
Page 17
Portable Desktop Mounting 4. Unlock the lever and remove the connection module from the base sta- tion. 5. Screw the connection module and mounting plate sub-assembly to a flat surface using four screws as shown in the figure below. Screws Position Screws Position 6.
Page 18
Portable Desktop Mounting 7. Move the base station up until the sphere is aligned with the smaller hole, then lock the lever to secure the connection module. Lock the lever BC9600 BASE STATIONS...
System Connections SYSTEM CONNECTIONS CAUTION: Connections should always be made with power off. The BC9630 (BC9600 + CM9630 connection module) provides a multi-inter- face connector for connections to a host and a power supply connector for an external power supply. To unlock the multi-interface cable, first lift the lever and then extract the cable, as indicated by the label next to the lever.
Page 20
System Connections RS232 BC9630 BC9631 The power supply is optional, the base station can be powered by the USB port. In this case, the full charging of an empty battery will take about 16 hours with an approved USB cable (type A) and 6.5 hours with an approved USB cable (type C) at ambient temperature.
Page 21
System Connections BC9631 ETHERNET BC9680 BC9681 POE connection BC9681 External Power Supply Brown: +10/30 VDC Blue: GND Black: Not Used QUICK REFERENCE GUIDE...
System Connections BC9681 Power Over Ethernet (PoE) Connection NAME DESCRIPTION Transmit Data + Transmit Data - Receive Data + Receive Data - DC1- Dc power - DC2- Dc power - DC1+ Dc power + DC2+ Dc power + M12 X-Coded Female Ethernet Network Connector Power can be applied to any of the data pairs according to the IEE 802.3af standard for Alternative A (Mid and Endspan) or Alternative B.
System Connections Connecting and Disconnecting the Cables Connecting BC9630 cables Connect the multi-interface cable first, then connect the power adapter cable. Finally, power on the base station. After connecting the power supply cable, secure it on the strain relief as shown in the figure below.
Page 25
System Connections Unlock the lever Press down the Cable clip cable clip Pull out the multi-interface cable and put the lever back into lock position. Lock position QUICK REFERENCE GUIDE...
System Connections Connecting BC9631 multi-interface cable Unscrew the no-tool screw to open the front door, connect the multi-inter- face cable, close the door and screw it back. Unscrew Insert Screw To disconnect the multi-interface cable, open the front door, pull out the cable and screw the front door back.
System Connections Connecting BC9680 cables Connect the Ethernet cable and then connect the power adapter cable. Finally, power on the cradle and lock the power cable on the strain relief. To disconnect the cables, first unlock the power cable and then pull it out. To disconnect the Ethernet cable, use a flat screwdriver to unlock the Ethernet clip.
RS232/USB-COM or Ethernet interface. It also allows upgrading the software of the connected device (see the Datalogic Aladdin™ Help On-Line for more details). Serial Configuration By connecting the BC963X to a PC through an RS232 or USB-COM interface cable, it is possible to send configuration strings from the PC to the BC963X.
Technical Specifications TECHNICAL SPECIFICATIONS The following table contains Physical and Performance Characteristics, User Environment and Regulatory information. PHYSICAL CHARACTERISTICS Color Black Height 9.8 cm (3.9'') Dimensions Length 24.3 cm (9.6'') Width 10.2 cm (4'') ELECTRICAL CHARACTERISTICS BC9630: Host power 5VDC +/-5%(*) or 10-30 VDC +/-5% External power 10-30 VDC +/-5% BC9631: Host power 5VDC +/-5% or 10-30 VDC +/-5%...
TECHNICAL SUPPORT Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to (www.datalogic.com). For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for.
The Warranty Period shall be three years from the date of shipment by Datalogic, unless otherwise agreed in an applicable writing by Datalogic. Datalogic will not be liable under the warranty if the Product has been exposed or subjected to any: (1) maintenance, repair, installation, handling, packaging, transportation, storage, operation or use that is improper or otherwise not in compliance with Datalogic’s instruction;...
Page 32
Datalogic S.p.A. and/or its affiliates • Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A. in many coun- tries, including the U.S. and the E.U.