COLD WATER TROUBLESHOOTING INDEX
Cold Water is not Cold 5°± 3°C (41°± 5°F)
Possible Reason
No power to refrigeration
system
Tank has run out of cold water.
Cold tank capacity is 4 Litres
for freestanding and 2 Litres
for mini.
Cold Water Thermostat
Refrigerant has run out
Compressor problem
Note: The Waterlogic Firewall reduces 7-log of waterborne bacteria, 5-log of viruses, and 4-log of
parasites potentially found in the drinking water. A small amount (about 50ml) of water remains in the
Firewall device after dispensing. This water does not remain permanently chilled, and will eventually
become room temperature after several hours. To ensure the next glass of water dispensed is
adequately chilled, Waterlogic recommends dispensing 100ml or more cup of water after long periods
of inactivity. The first 50ml will be near room temperature, and the remaining 100+ml will be very cold.
The mixture of these two temperatures will provide for an adequately refreshing, cold drink.
WL3 FW Manual
Check Green Heater & Compressor switch is on.
Turn Green Heater & Compressor Switch on.
I = ON
Wait for Cold Tank to chill water to temperature prior to
dispensing more cold water.
Greater capacity Waterlogic Water Treatment Systems are
available.
Check continuity of Thermostat with multimeter. Replace
Thermostat as required.
Run Compressor for at least ten minutes. If Condenser is not
warm, then refill the refrigerant.
If Compressor is not running, repair or replacement is
needed.
Solution
Page 56 - Revision: EU 17-09-2020