Advertisement

WL 850 HV
Technical Manual

Advertisement

Table of Contents
loading

Summary of Contents for WaterLogic WL850HV

  • Page 1 WL 850 HV Technical Manual...
  • Page 2: Table Of Contents

    Index Introduction Operational Information Creating Carbonated Water Components Layout Diagram Pre Delivery Inspection Procedures (PDI) Installation Procedures Operating Instructions Maintenance And Servicing Sanitizing The Machine Cleaning WL 850 HV Troubleshooting The WL 850 HV WL 850 HV Exploded Diagram WL 850 HV Wetted Parts Diagram WL 850 HV Main Parts Layout Diagram WL 850 HV Electrical Wiring Diagrams Technical Specifications...
  • Page 3: Introduction

    Introduction Thank you for purchasing the Waterlogic WL850HV water purifier. The WL850HV is suitable for use in a small or large office and it is designed to be connected to mains public drinking water supplies. Waterlogic International are using proven technology to clean and then purify your mains water supply and then chill the water so that you can enjoy great tasting and healthy still and sparkling water all the time.
  • Page 4: Operational Information

    Any change of the button configuration for use in hot water dispensing is the a) Cold, Hot & Sparkling responsibility of the distributor if so required. Waterlogic strongly advises against b) Cold, Ambient & Sparkling the use of a one button operation for a hot water. The PCB also has a UV failure c) Cold &...
  • Page 5 All water connection fittings are made by the John Guest Company and are approved The filtration system on the WL850HV is NSF approved two –stage filter. Stage to NSF standard 51. The machine is connected the water supply by a ¼” female one is a 10 micron screen;...
  • Page 6: Creating Carbonated Water

    Creating Carbonated Water CARBONATION The carbonation in the tank has been designed to a similar level to that in international soft drinks. Good carbonation depends on a combination of CO gas pressure, water pressure, water quality and temperature. CREATING CARBONATED WATER Understanding how it works.
  • Page 7: Components Layout Diagram

    Components Layout Diagram Hot and Cold WL850 HV Technical Manual - Version 1, November 2007...
  • Page 8: Pre Delivery Inspection Procedures (Pdi)

    2. Remove the top cover and the lower front panel and visually inspect the internals Waterlogic units may weigh over 25KG. We recommend caution when lifting. of the machine for any wires or pipes that may have come loose in transit.
  • Page 9: Installation Procedures

    8. The water temperature of the machine is factory set at 5ºC for still/cold water and or staff trained by Waterlogic International or an approved distributing agent. 87ºC for hot water. Sparkling water will automatically be colder than the still water as the cold tank system is designed to do this.
  • Page 10 19. The sparkling water quality is dependent on the water temperature, and the water/gas pressure. If the sparkling water is not sharp enough at first, then completely purge the sparkling tank of water by holding the dark blue button until no more water comes out of the machine and it starts blowing gas.
  • Page 11: Operating Instructions

    Operating Instructions Operating the machine is very simple. It’s as simple as selecting the option you want, and press the dispense button. THE MACHINE WILL DISPENSE FRESH WATER AT yOUR DISPOSAL. 1. Green LED indicates the power is ON. Flashing red LED indicates no water/pump time out.
  • Page 12: Maintenance And Servicing

    17. Inspect the water and electrical connections visually. 3. Remember there is no need to turn off the water with a Waterlogic Twist Filter; the 18. Turn on the green switch and allow the machine to cool and heat the water.
  • Page 13: Sanitizing The Machine

    5. Bypass the internal twist filter to avoid mixing sanitizing solution with the active carbon. CLEANING WL850HV 6. Connect the outlet of the Ametek housing to the inlet of the machine and connect 1. It is recommended to clean the machine at least once per week. The cleaning supply water pipe to the inlet of the Ametek housing.
  • Page 14: Troubleshooting The Wl850Hv

    3. Water has a Plastic or Funny Taste: 1) If the machine is new it may need to be 9. Factory sets the cold water at 5°C. Waterlogic strongly advice that you do not flushed. 2) Has the machine been unused over a long weekend? Then flush 5 litres of adjust the water to a colder temperature.
  • Page 15 Exploded Diagram Replacement Parts List WL850 HV Technical Manual - Version 1, November 2007...
  • Page 16 Wetted Parts Diagram WL850 HV Technical Manual - Version 1, November 2007...
  • Page 17 Main Parts Layout Diagram CHECK VALVE HOT WATER OUT HOT WATER OUT AIR VENT SOLENOID VALVE SOLENOID VALVE IN (Water) SPARKLING WATER OUT SOLENOID SUCK VALVE BACK SOLENOID COLD SAFETY VALVE SOLENOID SENSOR VALVE VALVE CONDENSER COLD SPARKLING TANK TANK TANK COMPRESSOR SOLENOID...
  • Page 18 Electrical Wiring Diagram Electrical Wiring Diagram Cold, Hot and Sparkling Cold, Ambient and Sparkling DANGER HIGH VOLTAGES PRESENT ON THIS PCB DANGER HIGH VOLTAGES PRESENT ON THIS PCB CARE MUST BE TAKEN WHEN LIVE TESTING CARE MUST BE TAKEN WHEN LIVE TESTING WL850 HV Technical Manual - Version 1, November 2007...
  • Page 19: Technical Specifications

    Technical Specifications WL850 HV WL850 HV WL850 HV WL850 Description MHCS Width Depth 38W-34D-114H 38W-34D-114H 38W-34D-47H 38W-34D-47H Height (CM) (CM) Water Dia ¼” Dia ¼” Dia ¼” Dia ¼” Connection Cold Water 5-8ºC 5-8ºC 5-8ºC 5-8ºC Temp Hot Water Temp 85-87ºC 85-87ºC 85-87ºC...
  • Page 20 Speak to a Water Expert USA, Canada and Mexico exportsales@waterlogic.com info@waterlogicusa.com + 353 1 293 1960 + 1 402 884 7212 WLI Trading Ltd. Waterlogic USA, 4141 N. 156th Street, Suite 4, 2nd Floor Beacon Court, Omaha, NE 68116 Sandyford, Dublin 18, Ireland www.waterlogic.com...