14 Workshop Manual
ABS submersible sewage pump XFP 80C - 150E
10
Oil Drain and Fill
10.1
Oil chamber
Plug
screw
DRAIN
10.
Motor chamber
Plug
screw
DRAIN
Drain
Loosen plug screw (74) enough to release pressure (see Health
and Safety Instructions page 3).
Place pump in horizontal position, sitting on discharge flange, with
motor housing supported from underneath.
Note: to prevent the pump from toppling over ensure it is
supported to lie flat on the discharge flange.
Position adequate container to receive waste oil.
Remove plug screw (74) and seal ring (75) from drain hole.
Fill
After the oil is fully drained lay the pump flat, and rotate so that
the drain hole is positioned to the top.
Note: when in this position the pump will not balance and must be
held by hand, or supported at both sides, to prevent it from toppling
over.
Select the required volume of oil from the oil-fill table (page 15)
and slowly fill with oil into the drain hole.
Refit plug screw and seal ring.
FILL
Drain
Remove volute, bottom plate and impeller (see page 8).
Loosen plug screw (76) enough to release pressure (see Health
and Safety Instructions page 3).
Using a hoist, suspend pump by the lifting hoop.
Position adequate container to receive waste oil.
Remove plug screw (76) and seal ring (77) from drain hole.
Fill
Remove lifting hoop and sit motor housing in support fixture (Sec
12.9.1) .
Select the required volume of oil from the oil-fill table (page 15)
and slowly fill with oil into the drain hole.
Refit plug screw and seal ring.
Refit impeller, volute and bottom plate (page 8).
Refit lifting hoop.
FILL
Need help?